Skip to main content

VRV H - Heat Pump Series
(RXYQ-BYM)

  • Available in

    Heat Pump

  • Capacities

    22.4kW-168kW

  • Type

    Outdoor Unit

  • Power Supply:

    3 Phase: 380-415V, 50Hz

  • Refrigerant

    R410A


Featuring unique functions within a new, large-capacity casing, the 6th generation VRV H - Heat Pump Series enables both cooling and heating operations using a single VRV system. The VRV H series adopts a novel casing design, allowing for a single module of up to 24 class (HP). Furthermore, these new models have achieved significant energy savings through improved technology. The operating performance has been enhanced in all aspects by incorporating innovative ideas, technologies, and a wide range of functions to bolster design flexibility, ease of installation, and reliability. Our advanced VRV technology offers greater benefits to various users within the air conditioning systems domain, including building owners, consultants, installers, and even building management.

Elevate your HVAC system to new heights with our cutting-edge VRV technology.

Minimum Energy Performance Standards

All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions.
  • Features

    • Compact Modular Design: 22 & 24HP model sits at just 1,750mm wide x 765mm deep x 1,660mm tall representing a 4% reduction in total footprint and 4% reduction in weight compared to the 5th generation model.
    • Enhanced Lineup: 3 new chassis designs (M, L & XL) with single modules starting at 8HP capacity. Thanks to the XL chassis, 22HP (61.5kW) & 24HP (67.0kW) single modules models are now also available.
    • Energy Saving: Software Technology - VRT Smart II Control - Further improvement of energy savings is achieved due to optimal control of the outdoor airflow rate.
    • Easy Installation: The sealed electrical box boasts an IP55 ingress protection rating, ensuring robust safeguarding against dust and moisture. It features a new service window that offers convenient access to a versatile digital display, simplifying the commissioning and troubleshooting processes. Additionally, its design incorporates separate wiring and piping pathways, facilitating swift and hassle-free installation and servicing.
    • Increased refrigerant piping Length and height difference extension: Refrigerant piping lengths of up to 165m are possible and the maximum height difference between the indoor unit and the outdoor unit has been extended to 110m which is an improvement of 20m from the 5th generation model.
    • Improve Operation Limits: Refrigerant cooled inverter PCB with three cooling points of contact, allows for operation at a maximum ambient temperature of 52°C*.

      *Limited to 49°C if outdoor is above indoor and height difference >90m

    Features VRV H
     

    VRV Smart II Control
    Provides ultimate comfort & energy savings by automatically optimising core system elements such as variable refrigerant temperature (VRT), indoor unit fan speed, compressor speed and now also outdoor unit fan speed.

  • Technology

    1. P-Type Compressor: Optimised for part load performance and delivers a 50% part load EER of up to 7.61
    2. VRV II Smart Technology: Variable refrigerant temperature with automatic indoor unit and outdoor unit fan speed regulation.
    3. Refrigerant Cooled PCB: Enables max operation limit of up to 52°C ambient conditions.
    4. IP55 Electrical Component Box: Blocks the ingress of debris and moisture to prevent unexpected failures.
    5. 7 Segment Digital Display: Allows for easy commissioning and troubleshooting.
    6. Waffle Fin Heat Exchanger: Maximum surface area for greater heat exchange and COP
    7. Reinforced Casing Design: Improved frame structure provides better resistance tot eh elements.
    8. Outdoor Rotor DC Motor: 10 pole DC outer diameter rotor motor for improved torque delivery in a compact form factor.
    9. Propeller Fan: Sharp edge fan blade curvature reduces vibration and pressure loss.